IUI Laminar Air Flow 2ftx2ft – Andrology Workstation 2ftx2ft – IUI Workstation 2ftx2ft

150,000.00 (GST extra)

IUI Laminar Air Flow 2ftx2ft – Andrology Workstation 2ftx2ft – IUI Workstation 2ftx2ft is a very important product of IUI Lab Set Up. This equipment throws class 100 purifies air over the working area of the table.

Dispatch Time: 15-25 Days

No item will be exchanged or refunded. All items are warranted by the manufacture only.

Description

IUI Laminar Air Flow 2ftx2ft – Andrology Workstation 2ftx2ft – IUI Workstation 2ftx2ft

IUI Laminar Air Flow 2ftx2ft – Andrology Workstation 2ftx2ft – IUI Workstation 2ftx2ft is used to complete the IUI procedures. All types of IUI (Intrauterine insemination) procedures are done on top of its table area.

IUI Laminar Air Flow 2ftx2ft - Andrology Workstation 2ftx2ft - IUI Workstation 2ftx2ft

Technical Specification:-

Make for KG Medical Industries
Model GI with powder Coated Vertical
Work Table SS304G with Mirror Finish Surface
Cleanliness Class 100
Particle Retention 0.3 Micron & above
Velocity 90 Feet/Minute ± 20% or above or below
Noise Level 56 decibel ± 5%- Centrifugal type
Illumination 40 Watts, 4 Ft. Fluorescent Tubes with Diffusers
Disinfection UV light
Power Sockets 2  Nos. of 5 Amps Sockets for Future application or as per model
Temp. Accuracy ± 0.5°C (Room Temperature needs to maintain 9°C less than set pt.)
Temp. Uniformity 95% ±  5%
Power Supply 220 Volt Single Phase, 50 Hz.  1.2 KVA

HEPA- Filter

Media Ultra clean glass Fiber paper – Imported
Casing Epoxy coated CRCA Frame
Seperators Minipleat no seperators
Retention 0.3 Microns and above
Efficiency 99.97%

Pre- Filter

Media Synthetic, Non-woven polyster fibers
Casing Enamal Painted CRCA Frame
Retention 10-15 Microns
Efficiency 99.97%

Uses

Product Uses Locations
  1. Infertility Hospital
  2. Infertility Clinics
  3. Semen Analysis Labs
  4. IVF Labs (In Vitro Fertilization )
  5. IUI Labs (Intrauterine Insemination Labs).
Product SKU IUI_Laminar_Air_Flow
Product Warranty One Years.
Applicable GST on Product Current GST Tax is 18 % or can change as per government orders.

Advance IUI Laminar Air Flow 2ftx2ft - Andrology Workstation 2ftx2ft - IUI Workstation 2ftx2ft

How much space is required for installation of IUI Laminar Air Flow 2ftx2ft – Andrology Workstation 2ftx2ft – IUI Workstation 2ftx2ft:-

The length and width of IUI Laminar Air Flow 2ftx2ft – Andrology Workstation 2ftx2ft – IUI Workstation 2ftx2ft is about 2 feet x , 2 feet to fit it. At least this or more space is required this machine is fitted inside the IUI lab. So the buyer should follow how much space the entire IUI lab requires.

However, at least 100 square feet of area is required for any standard IUI lab to install all the basic IUI lab equipment and work properly. IUI lab size should not be increased too much because if it is increased more than required then it will be more difficult to keep class 100 standard of air quality of IUI lab.

Yet due to some reason the size of the lab increases then you can also use air cleaner for IUI lab. Using an air cleaner will solve the problem of air quality.

Andrology Workstation 2ftx2ft - IUI Laminar Air Flow 2ftx2ft - IUI Workstation 2ftx2ft

Cleaning and Maintenance of IUI Laminar Air Flow 2ftx2ft – Andrology Workstation 2ftx2ft – IUI Workstation 2ftx2ft

70 percent alcohol is required to clean all types of IUI lab and IVF lab equipment. However, we are advised that first of all the product should be cleaned with double distilled water and only then should be cleaned with 70 percent alcohol.

The equipment should never be cleaned with 100% alcohol. It can damage the equipment and can also change the color of the equipment or it can also cause color torn.

We fit pre filter and Hepa filter in our product. Hepa filter cannot be cleaned. It gets spoiled from time to time and has to be changed but pre filter should be cleaned from time to time so we insist that pre filter which is fitted at the back of our product. Should be cleaned with air pressure, for this you can use a vacuum cleaner.

Product Warranty / Returnable

  1. Standard Warranty: One Year.
  2. Returnable: Non-Returnable.